Diurnal variation of flow-mediated dilatation in healthy humans

Abstract

Introduction

The measurement of flow-mediated dilatation (FMD) via ultrasound has been established as a reliable non-invasive measurement of endothelial function. However, the guidelines mention nothing regarding diurnal variation of FMD. Thus, we investigated the FMD in healthy people and diurnal variation of FMD.

Methods

Twenty-five apparently healthy persons participated in this study. All participants had no history of cardiovascular diseases, hypertension, or diabetes and used any medication. For each volunteer, the measurements were repeated in the morning and afternoon on two different days. We checked capillary blood glucose, total cholesterol, triglyceride, high-density lipoprotein (HDL), and low-density lipoprotein (LDL)-cholesterol.

Results

The average of FMD measurements was 8.45% ± 2.39%. The mean values of systolic and diastolic blood pressure, heart rate, lipid profiles, and glucose levels were similar between the morning and afternoon measurements after 9-h fasting. There was no significant difference of FMD measurements between the morning and afternoon (8.32% ± 2.27% and 8.58% ± 2.56%, p = 0.329). Moreover, there was significant correlation between FMD in the morning and afternoon (r = 0.856, p < 0.001).

Conclusions

Our study shows measurement of FMD was 8.45% in healthy Koreans. Also, there was no significant difference of FMD measurements between the morning and afternoon.

Introduction

Endothelial dysfunction is a systemic disorder and an important factor in the pathogenesis of atherosclerosis, hypertension, and heart failure [1-3]. Impaired endothelial function is associated with increased risk for cardiovascular events [4-6]. The measurement of flow-mediated dilatation (FMD) via ultrasound has been established as a reliable non-invasive measurement of endothelial function [7]. As FMD becomes more and more important in clinical practice to evaluate the risk of coronary heart disease, reproducibility should be available, preferably during the course of the whole day for practical reasons. Reported by the guidelines for the ultrasound assessment endothelial-dependent flow-mediated vasodilation of the brachial artery to decrease sensitivity and establish more reliable FMD measurements, smoking, vitamin supplementation, alcohol intake, and food intake should be controlled [8-12]. However, the guidelines mention nothing regarding a diurnal variation of FMD. Since only a few studies showed that endothelial-dependent FMD had diurnal variation, it was unclear whether there was the effect of the time of measurement on FMD outcome or not [13-15]. Furthermore, it is lack of data about FMD and the absolute values obtained vary considerably across studies in Korea [16-18].

Thus, the purposes of this study were (1) to examine the FMD in Korean and (2) to investigate diurnal variation of FMD.

Methods

Study population

Twenty-five apparently healthy persons participated in this study. We evaluated physical history and clinical history including age, gender, weight, height, body mass index (BMI), blood pressure, heart rate, and history of smoking. All participants had no history of cardiovascular diseases, hypertension, or diabetes and used any medication or vitamin preparation. The Institutional Review Board of Wonkwang University Hospital approved the study, and all participants agreed to participate after reading a detailed informed consent form (WKUH 201412-HRE-093).

FMD measurements

We measured FMD of brachial artery according to the International Brachial Artery Reactivity Task Force guidelines using an ultrasound system equipped with an edge-tracking system for two-dimensional (2D) image and a pulsed Doppler flow velocimeter for automatic measurement (UNEXEF; Unex Co. Ltd., Nagoya, Japan) [8]. The system is comprised of a 10-MHz linear array transducer probe. To control for confounding variables, prior to testing, subjects were instructed to fast and abstain from exercise, caffeine, and tobacco for at least 6 h. For each volunteer, the measurements were repeated at 08:00 to 10:00 and 16:00 to 18:00 on two different days. One observer measured FMD of brachial artery in our study. The whole study was performed by subjects rested in the supine position for 10 min before each measurement. Vascular measurements were performed in the supine position in a quiet, temperature-controlled room of the echocardiography laboratory. Initially, longitudinal 2D images were acquired. After the baseline recording of brachial artery diameter, the blood pressure cuff placed on the subject’s right forearm was inflated 50 mmHg above their systolic blood pressure, leading to arterial occlusion. The diameter of the artery was monitored continuously at the same point, and the maximum dilatation from 90 s after deflation was recorded. FMD was calculated as the difference between the maximum post-occlusive diameter and the baseline diameter, relative to the baseline diameter and expressed as a percentage.

Laboratory measurement

Blood samples were drawn in the morning and afternoon after at least 6 h fasting, respectively. Before measuring FMD, blood sampling was done. On both occasions, we checked capillary blood glucose, total cholesterol, triglyceride, high-density lipoprotein (HDL), and low-density lipoprotein (LDL) by using test kit (Lipid Pro; Infopia Co. Ltd., Korea).

Statistical analysis

All measurements were expressed as mean ± standard deviation (SD) or absolute number (percentage). Student t-test was used to test for significant differences where appropriate. Pearson’s correlation was used to test bivariate correlations as well. A P value <0.05 was considered as significant. Statistical analyses were performed using SPSS 19.0 for windows (SPSS Inc., Chicago IL, USA).

Results

Subject characteristics

The study population consists of thirteen male and twelve female subjects. The mean age of the subjects was 35.1 ± 9.8 years. They had a mean BMI of 23.4 ± 2.3 kg/m2. There were nine current smokers. The mean values of systolic and diastolic blood pressure, heart rate, lipid profiles, and glucose levels were similar between the morning and afternoon measurements after 9 h fasting (Table 1). Only fasting period was longer in the morning group than afternoon (10.9 ± 1.9 vs 9.2 ± 2.6 h, p = 0.008).

Table 1 Subject characteristics ( n= 25)

Brachial artery characteristics

The brachial artery characteristics in the morning and afternoon measurements are shown Table 2. The average brachial artery diameter and FMD measurements were 3.61 ± 0.42 mm and 8.45% ± 2.39%. FMD measurements in the morning and afternoon were 8.32% ± 2.27% and 8.58% ± 2.56%, respectively. There was no significant difference of FMD measurements between the morning and afternoon. The mean ± SD difference between FMD in the morning and afternoon was – 0.26% ± 1.32%. There was also no significant difference between the brachial artery diameter in the two recordings (− 0.01 ± 0.09 mm).

Table 2 Brachial artery characteristics

In the correlation analysis, there was significant correlation between FMD in the morning and afternoon (r = 0.856, p < 0.001) (Figure 1). Similarly, brachial artery diameter revealed a significant correlation between both recordings (r = 0.983, p < 0.001).

Figure 1
figure 1

Correlation between flow-mediated dilatation (FMD) in the morning and afternoon. r, correlation coefficient, p, p value by Pearson’s correlation analysis.

Discussion

In this study, our data shows that the average of FMD was about 8.5%. Moreover, there was no significant difference and significant correlation between FMD in the morning and afternoon. In Korea, there is sparse data concerning FMD in healthy people. In the study by Park et al., the average of FMD in 25 healthy people, a mean aged 54 years, was 14.3% [17]. The study also showed that FMD was 18.0% in 13 young healthy people, a mean age of 26 years. In the study by Bae et al., it showed FMD in 10 young healthy people, a mean age of 26 years, was 13.0% [18]. These studies showed the differences in FMD measurement compared with the results of our study, although brachial artery diameters were similar in our study (3.6 and 3.58 vs 3.61 mm). Since the experimental group was too small in these studies including our own study, it probably led to have an increase in bias and difference of FMD. Moreover, the automatic measurement is more reproducible and less subjective [19]. In the two studies mentioned above, FMD was analyzed by calipers without a system for the automatic evaluation. But we analyzed FMD with automatic measurement system. Therefore, we should consider a probable bias from manual measurement in the two studies mentioned above. In the study by Hwang et al., it showed FMD was 8.98% in 74 young healthy volunteers, with a mean age 22 years [16]. There was no any significant difference compared with the 8.45% from our study. In the study by Vlachopoulos et al., it showed FMD was about 6.0% in healthy people, with a mean age 32 years [11]. However, only 12 subjects participated in this study. Therefore, a large scale study should be performed to achieve precise results.

In our present study, the results show the reproducibility of the FMD measurement regardless of the time of day, and it is not necessary to standardize the time of FMD measurement. It is widely known that a principle mediator of FMD is endothelium-derived nitric oxide (NO) [20,21]. In addition, there is a close interaction between the sympathetic nervous system and NO [22]. Diurnal changes in sympathetic activity are generally held responsible for diurnal changes in NO availability. However, in our study, sympathetic activity such as systolic blood pressure, diastolic blood pressure, and heart rate was similar in the morning and afternoon. Thus, we assume that it may lead to insignificant diurnal variation between FMD in the morning and afternoon.

Moreover, the concept that the observed diurnal pattern of FMD reflected a diurnal variation in NO production was not supported in some studies. In the study by Järvisalo et al., the plasma levels of NO degradation products showed significant variation with the highest levels in the morning and lowest in the afternoon but were not significantly associated with FMD [23]. In a previous study in healthy pre-menopausal women, the urinary excretion or plasma levels of nitrate did not display diurnal variation or associate with FMD [15]. Thus, it will be necessary to continue the research in a large-scale and well-controlled study.

To standardize the assessment of FMD, most study groups have performed the measurements in the morning on fasting patients. However, it leads to a limit of the wide-scale use of this methodology in routine clinical practices. Previous studies showed that postprandial changed in endothelial function are controversial [11,12,24]. Our study was well controlled for diet, as a result, triglyceride and glucose levels were similar in the morning and afternoon. Therefore, it is reasonable to assume that diet is a major factor effect on FMD compared with the time of measurement on FMD.

Our study has some limitations. Firstly, laboratory findings such as total cholesterol, triglyceride, HDL, LDL, and glucose were only analyzed by capillary blood. Even if samplings of capillary blood showed no difference in the two recordings, it did not represent the serum levels. To overcome this limitation, we provided a sufficient fasting period to all subjects. Secondly, we did not consider intra-observer variability of FMD. However, we did check FMD by automatic measurement. We believe that it leads to more reproducible and less subjective results.

Conclusion

Measurement of FMD is 8.45% in healthy Koreans, and our results show there were no significant differences between FMD in the morning and afternoon. It will be helpful to evaluate endothelial function in routine clinical practice.

Abbreviations

2D:

two-dimensional

FMD:

flow-mediated dilatation

HDL:

high-density lipoprotein

LDL:

low-density lipoprotein

NO:

nitric oxide

SD:

standard deviation

References

  1. Bonetti PO, Lerman LO, Lerman A. Endothelial dysfunction. A marker of atherosclerotic risk. Arterioscler Thromb Vasc Bio. 2003;23:168–75.

    Article  CAS  Google Scholar 

  2. Rizzoni D. Endothelial function in hypertension: fact or fantasy? J Hypertens. 2002;20:1479–81.

    Article  CAS  PubMed  Google Scholar 

  3. Drexler H, Hayoz D, Münzel T, Horning B, Just H, Brunner HR, et al. Endothelial function in chronic congestive heart failure. Am J Cardiol. 1992;69:1596–601.

    Article  CAS  PubMed  Google Scholar 

  4. Shechter M, Shechter A, Koren-Morag N, Feinberg MS, Hiershc L. Usefulness of brachial artery flow-mediated dilation to predict long-term cardiovascular events in subjects without heart disease. Am J Cardiol. 2014;113:162–7.

    Article  PubMed  Google Scholar 

  5. Wildansky ME, Gokce N, Keaney JF, Vita JA. The clinical implication of endothelial dysfunction. J Am Coll Cardiol. 2003;42:1149–60.

    Article  Google Scholar 

  6. Lerman A, Zeiher AM. Endothelial function cardiac events. Circulation. 2005;111:363–8.

    Article  PubMed  Google Scholar 

  7. Uehata A, Lieberman EH, Gerhard MD, Anderson TJ, Ganz P, Polak JF, et al. Noninvasive assessment of endothelium-dependent flow-mediated dilation of the brachial artery. Vasc Med. 1997;2:87–92.

    CAS  PubMed  Google Scholar 

  8. Corretti MC, Anderson TJ, Benjamin EJ, Celermajer D, Charbonneau F, Creager MA, et al. Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery: a report of the International brachial artery reactivity task force. J Am Coll Cardiol. 2002;39:257–65.

    Article  PubMed  Google Scholar 

  9. Granberry MC, Smith III ES, Troillett RD, Eidt JF. Forearm endothelial response in smokeless tobacco users compared with cigarette smokers and nonusers of tobacco. Pharmacotherapy. 2003;23:974–8.

    Article  PubMed  Google Scholar 

  10. Levine GN, Frei B, Koulouris SN, Gerhard MD, Keaney Jr JF, Vita JA. Ascorbic acid reversed endothelial vasomotor dysfunction in patients with coronary artery disease. Circulation. 1996;93:1107–13.

    Article  CAS  PubMed  Google Scholar 

  11. Vlachopoulos C, Tsekoura D, Tsiamis E, Panagiotakos D, Stefanadis C. Effect of alcohol on endothelial function in healthy subjects. Vasc Med. 2003;8:263–5.

    Article  PubMed  Google Scholar 

  12. Vogel RA, Corretti MC, Plotnick GD. Effect of a single high-fat meal on endothelial function in healthy subjects. Am J Cardiol. 1997;79:350–4.

    Article  CAS  PubMed  Google Scholar 

  13. Etsuda H, Takase B, Uehata A, Kusano H, Hamabe A, Kuhara R, et al. Morning attenuation of endothelium-dependent, flow-mediated dilation in healthy young men: possible connection to morning peak of cardiac events? Clin Cardiol. 1999;22:417–21.

    Article  CAS  PubMed  Google Scholar 

  14. Kollias GE, Stamatelopoulos KS, Papaioannou TG, Zakopoulos NA, Alevizaki M, Alexopoulos GP, et al. Diurnal variation of endothelial function and arterial stiffeness in hypertension. J Hum Hypertens. 2009;23:597–604.

    Article  CAS  PubMed  Google Scholar 

  15. Ringqvist A, Caidahl K, Petersson AS, Wennmalm A. Diurnal variation of flow-medicated vasodilation in healthy premenopausal women. Am J Physiol Heart Circ Physiol. 2000;279:H2720–5.

    CAS  PubMed  Google Scholar 

  16. Hwang IC, Kim KH, Choi WS, Kim HJ, Im MS, Kim YJ, et al. Impact of acute exercise on brachial artery flow-mediated dilatation in young healthy people. Cardiovasc Ultrasound. 2012. doi:10.1186/1476-7120-10-39.

  17. Park KR, Bae JH. Comparison of the endothelial function between healthy subjects and patients with coronary artery disease or risk factors of atherosclerosis. Kor Circ J. 2001;31:544–50.

    Article  Google Scholar 

  18. Bae JH, Kim KB, Kim KS, Han SW, Kim YN, Park SY, et al. The effect of vitamin E on the endothelial function following a single high-fat meal in normal subject, patients with coronary heart disease and patients with diabetes. Kor Circ J. 1998;28:1538–51.

    Article  Google Scholar 

  19. Donald AE, Halcox JP, Charakida M, Storry C, Wallace SM, Cole TJ, et al. Methodological approaches to optimize reproducibility and power in clinical studies of flow-mediated dilation. J Am Coll Cardiol. 2008;51:1959–64.

    Article  PubMed  Google Scholar 

  20. Rubanyi GM, Romero JC, Vanhoutte PM. Flow-induced release of endothelium-derived relaxing factor. Am J Physiol. 1986;250:H1145–9.

    CAS  PubMed  Google Scholar 

  21. Pohl U, Holtz J, Busse R, Bassenge E. Crucial role of endothelium in the vasodilator response to increased flow in vivo. Hypertension. 1986;8:37–44.

    Article  CAS  PubMed  Google Scholar 

  22. Jordan J, Tank J, Stoffels M, Franke G, Christensen NJ, Luft FC, et al. Interaction between beta-adrenergic receptor stimulation and nitric oxide release on tissue perfusion and metabolism. J Clin Endocrinol Metab. 2001;86:2803–10.

    CAS  PubMed  Google Scholar 

  23. Järvisalo MJ, Jartti L, Marniemi J, Rönnemaa T, Viikari JS, Lehtimäki T, et al. Determinants of short-term variation in arterial flow-mediated dilatation in healthy young men. Clin Sci. 2006;110:475–82.

    Article  PubMed  Google Scholar 

  24. Raitakari OT, Lai N, Griffiths K, McCredie R, Sullivan D, Celermajer DS. Enhanced peripheral vasodilation in humans after a fatty meal. J Am Coll Cardiol. 2000;36:417–22.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors would like to thank Su Jeong Yu who helped in collecting the data and select figure.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Kyeong Ho Yun.

Additional information

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

KYC drafted the manuscript. YKH conceived of the study and participated in its design and coordination. RSJ, KNH, OSK, and JJW directed and supervised the manuscript. LMR and LJM helped in performing the statistical analysis. WSH, JJW, LJH, HKB, and JYH helped draft the manuscript. All authors read and approved the final manuscript.

Rights and permissions

Open Access  This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made.

The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder.

To view a copy of this licence, visit https://creativecommons.org/licenses/by/4.0/.

The Creative Commons Public Domain Dedication waiver (https://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kim, Y.C., Yun, K.H., Woo, S.H. et al. Diurnal variation of flow-mediated dilatation in healthy humans. Clin Hypertens 21, 6 (2015). https://doi.org/10.1186/s40885-015-0019-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s40885-015-0019-4

Keywords